When it comes to versatility, the OHAUS Starter Series of Portable Meters are second to none. With an IP54-rated protective casing shielding the meter from water and/or dust damage, the compact and ergonomically design is adaptable for a wide array of environments. Highlighted by up to 250 hours of operation time and 30 sets of memory data, the Starter Portable Meters make for the most reliable lab partners, whether inside or out. more ... |
Features
When it comes to versatility, the OHAUS Starter Series of Portable Meters are second to none. With an IP54-rated protective casing shielding the meter from water and/or dust damage, the compact and ergonomically design is adaptable for a wide array of environments. Highlighted by up to 250 hours of operation time and 30 sets of memory data, the Starter Portable Meters make for the most reliable lab partners, whether inside or out.
Portable Meters Packed with Productive Features
The Starter Series of portable water analysis meters was created with versatility in mind. They can be operated in the lab with the support of the built-in stands or in the field thanks to their lightweight design. With a clear, well-organized LCD screen and five clearly marked keys, utilizing the Starter Series is simple for novices and professionals alike. The portable Starter Series also boasts IP54 protection which shields the meter from damage by water and dust particles and it also offers an integrated labeling area which can be customized for quick identification. Each meter can store 30 sets of data memory and has the ability to quickly recall calibration data and stored information with one quick touch.
Starter 300C Conductivity Meter Meter
Starter 300C is the reliable and accurate choice for measurement of the
conductivity and TDS levels of liquids. With a variety of features that protect
the meter from more extreme elements, Starter 300C can be used for a wide
variety of applications
- The 4-pole linear electrode offers a large conductivity range that safeguards
itself from polarization and pollution effects
- Automatic temperature compensation with an adjustable temperature
coefficient
After more than a century of perfecting the art of measurement through our durable weighing products, OHAUS precision is now available in the form of a portable water conductivity meter. This portable meter offers convenience, reliability and durability in one compact design.
Model |
ST300-B |
ST300 |
ST300-G |
ST300C-B |
ST300C |
ST300C-G |
ST300D-B |
ST300D |
ST300D-G |
Package Includes |
300 Meter with IP54 Sets, Electrode Clip Wrist Strap and 4 AAA Batteries (Electrode not included) |
300 Meter, ST320 3-in-1 Plastic Gel pH Electrode and pH Buffer Powder Sachet |
ST300-B, ST320 3-in-1 Plastic Gel pH Electrode, pH Buffer Powder Sachet (4.01, 7.00, 10.01), Portable Bag |
Starter 300C Meter, Conductivity Standards 1413µs/cm and 12.88mS/cm (20 ml bottles), IP54 Sets, Electrode Clip, Wrist Strap, 4 AAA Batteries (Electrode not included) |
300C Meter, with STCON3 4-Pole Conductivity Electrode (70 µs/cm-200 ms/cm, 2 Small Bottles of Standard Conductivity Solution - 1413 µS/cm and 12.88 ms/cm, IP54 Sets, Electrode Clip, Wrist Strap, 4 AAA Batteries |
ST300C-B Package, STCON3 4-Pole Conductivity Electrode (70 µs/cm-200 mS/cm), Portable Bag |
300D Meter with IP54 Sets, Electrode Clip, Wrist Strap and 4 AAA Batteries (Electrode not included) |
300D Meter with STDO11 Galvanic DO Electrode, and STTEMP30 Temperature Electrode |
ST300D-B Package with STDO11 Galvanic DO Electrode, STTEMP30 Temperature Electrode, Portable Bag |
Measurement Range |
0.00 - 14.00 pH -1999 - 1999 mV 0°C - 100°C |
0.0 µS/cm - 199.9 mS/cm 0.1 mg/l - 199.9 g/l (TDS) 0°C - 100°C |
0.0 - 199.9%;200 - 400% 0.00 - 12.99;20.0 - 45.0 mg/L 0.00-19.99;20.0 - 45.0 ppm 0 - 50°C |
Measurement Resolution |
0.01pH 1 mV 0.1°C |
Automatic Range 0.1°C |
0.1%;1% 0.1 mg/L;1 mg/L 0.01 ppm;0.1 ppm 0.1°C |
Barometric Range |
N/A |
N/A |
375 - 825 mmHg 500 - 1100 mbar 500 - 1100 hPa |
Barometric Resolution |
N/A |
N/A |
1 mmHg 1 mbar 1 hPa |
Error Limits |
± 0.01pH ± mV ± 0.5°C |
± 0.5% of the Measured Value ± 0.3°C |
± 1%; ± 0.33°C |
Calibration |
3 Points 1 Predefined Buffer Group |
1 Point 3 Predefined Buffer Groups |
1 or 2 Points 100% and 0% |
Memory |
30 Measurements Last Calibration Data |
30 Measurements Last Calibration Data |
30 Measurements Last Calibration Data |
Power Supply |
4 AAA > 500 Operating Hours |
4 AAA > 250 Operating Hours |
4 AAA > 250 Operating Hours |
Size / Weight |
90 W x 150 D x 35 H 0.18kg (without batteries) |
90 W x 150 D x 35 H 0.16kg (without batteries) |
90 W x 150 D x 35 H 0.18kg (without batteries) |
Display |
Liquid Crystal |
Liquid Crystal |
Liquid Crystal |
Input |
BNC, Impedance > 10e+ 12 Ω Cinch, 30 k Ω |
Mini-Din |
BNC Cinch, NTC 30k Ω |
Temperature Compensation |
ATC & MTC |
ATC, Linear: 0.00 %/°C = 10.00%/°C Reference Temperature 20 & 25 °C |
ATC & MTC |
Salinity Compensation |
N/A |
N/A |
0.0 to 50.0 ppt |
IP Protection |
IP54 |
IP54 |
IP54 |
Housing |
ABS |
ABS |
ABS |
×