AND Weighing AD-4212A-600 Precision Weighing Sensor, 610 X 0.001 g with RS-232C
High speed response of 0.8 seconds and high precision weighing resolution of 0.1mg using Super Hybrid Sensor (SHS) technology for an extremely effective weighing system ! more ...
Laboratory Equipment > Analytical Balances > Milligram - 1 mg
AND Weighing AD-4212A-600 Precision Weighing Sensor, 610 X 0.001 g with RS-232C


Price: $4,080.00


Available to Ship







Overview

High speed response of 0.8 seconds and high precision weighing resolution of 0.1mg using Super Hybrid Sensor (SHS) technology for an extremely effective weighing system !
Free Ground Shipping within the 48 continental US States
5 Year Manufacture Warranty
Manufature: AND Weighing
SKU: AD-4212A-600
Weight: 4.00 lb

  Features

AD-4212A

High speed response of 0.8 seconds and high precision weighing resolution of 0.1mg using Super Hybrid Sensor (SHS) technology for an extremely effective weighing system !
To improve productivity, you can create your own weighing system using the AD-4212A Precision Weighing Sensor. The compact design, as well as the separate weighing unit and display unit, ensure easy installation of the SHS at any stage of your weighing system.

High speed weighing response time
The SHS (Super Hybrid Sensor) offers a high speed weighing response time of approximately 0.8 seconds for 1mg weighing sensitivity and approximately 1.1 seconds for 0.1mg weighing sensitivity.

High resolution and capacity
Available models include 110g x 0.1mg, 210g x 1mg, 610g x 1mg and 1100g x 1mg.

Compact design
The weighing sensor unit is extremely compact ( 80 x 230 x 90 mm ) and ideal for easy installation with weighing systems.

Separate weighing sensor unit and display unit
The weighing sensor unit and display unit are connected with a cable 2m in length. An optional 3m cable ( OP-07 ) makes a maximum length of 5m possible for diverse applications. ( Can be extended further with RS-232C . ) It is easy to install the display unit into the panel of the control box providing easy operation and space economization.

A three-level comparator output (HI, OK or LO indicator) with I/O, as well as a Buzzer function, provide a simple and easy design solution for any precise weighing system.

External input function
The Re-Zero and Print key function can be controlled externally using the I/O D-Sub 25-pin connector.

Auto Power ON and OFF function
When the balance is plugged in, the ON function is automatically displayed. The OFF function will activate automatically if the balance is not operated for 10 minutes.

Auto Zero display after data output
Possible to set the display to automatically adjust to Zero after weight data is output.

Full Digital Calibration function
Simple and easy to calibrate with standard calibration mass for weighing accuracy.

Response Speed setting function
Function available to select optimum response speed from FAST, MID or SLOW.

WinCT software
Windows Communication Tools (WinCT) software for the high-speed transmission of weight data to a PC, and the ability to control the AD-4212A by sending commands.

Data memory function
Capable of storing any of the following; 200 weight measurements, 100 weight measurements with time & date, 50 calibration & calibration test measurements, 20 unit weight measurements for counting mode or 20 comparator setting limits values.

RS-232C
Standard interface function of bi-directional RS-232C for weighing data transmission and control of the AD-4212A.

Ethernet interface
Optional Ethernet interface (OP-08) for high-speed weight data transmission and multi-weighing lines application. ( Comes with application software WinCT-plus in CD-ROM. )

Applications

Self-check function
Easy to evaluate the performance of the AD-4212A.

“CLr ” Clear function
Returns to original factory settings for calibration data, function table, comparator value and data memory.

Bubble spirit level and adjustable leveling foot
Easy to level the weighing sensor unit for more accurate weighing applications.

Capacity indicator
Possible to read capacity being weighed from 0% to 100% of weighing range.

Durable weighing sensor unit and display unit
Aluminum die casting case coated with strong paint, which even protects from hydrogen peroxide.

Multi weighing units
Possible to use weighing unit incorporating counting mode with ACAI (Automatic Counting Accuracy Improvement) and Percent mode.

Product Features

  Specifications

Model AD-4212A-100 AD-4212A-200 AD-4212A-600 AD-4212A-1000
Weighing capacity 110 g 210 g 610 g 1100 g
Minimum weighing value 0.1 mg 0.001g
Stabilization time (Typical) 0-30 g: Approx. 1.1 sec 0-30 g: Approx. 0.8 sec 0-30 g: Approx. 0.9 sec 0-30 g: Approx. 0.9 sec
30-110 g: Approx. 1.3 sec 30-210 g: Approx. 1.0 sec 30-610 g: Approx. 1.1 sec 30-1100 g: Approx. 1.1 sec
Repeatability (Standard deviation) 0.15 g 0.001g
Linearity ±0.3 mg ±2 mg ±3 mg
Sensitivity drift (10 °C to 30 °C) ±2 ppm/ °C
Weighing pan 50 mm × 50 mm 70 mm × 70 mm
Operating environment 5°C to 40°C (41°F to 104°F), 85%RH or less (no condensation)
Display refresh rate 10 times/second (5 times/second can be selected)
Connection cable Approx. 2m (between weighing unit and display unit)
Power supply AC adaptor
Power consumption Approx.11VA (supplied to the AC adaptor)


  Other Models

AND Weighing AD-4212A-200 Precision Weighing Sensor, 210 X 0.001 g with RS-232C

AND Weighing AD-4212A-600 Precision Weighing Sensor, 610 X 0.001 g with RS-232C

AND Weighing AD-4212A-100 Precision Weighing Sensor, 110 X 0.1 mg with RS-232C

AND Weighing AD-4212A-1000 Precision Weighing Sensor, 1100 X 0.001 g with RS-232C